follow us on social media
FieldLogger is a versatile, powerful, and yet cost-effective data logger handling analog, digital, and other types of variables with high resolution and speed. It is a high performance and high connectivity equipment and yet easy to configure and operate.
It has 8 configurable analog inputs that can read thermocouples, Pt100, Pt1000, voltage and current signals. It also has 2 relay outputs and 8 digital ports individually configurable as inputs or outputs.
Up to 128 mathematical channels can be used to perform operations on the measured values. Up to 32 alarm events can be detected, allowing output activations, e-mails and SNMP traps sending.
Its RS485 interface can operate as a Modbus RTU master or slave. As a master, it can read and log up to 64 external channels. It has a 10/100 Mbps Ethernet interface that allows for access through a browser (HTTP), FTP (client and server), e-mails sending (SMTP), SNMP and Modbus TCP.
FieldLogger has one USB interface to be connected to a computer (for configuration, monitoring and data download) and another USB port for plugging a flash driver for data retrieval. The 512k logging basic memory is used to store data and it can be greatly expanded with an SD card.
An exclusive color HMI can be attached or remotely installed for local indication or configuration. A user-friendly configurator software can be accessed by Ethernet, USB or RS485 and also provides means for on-line monitoring, logged data downloading and exporting to spread sheets and other formats.
Remote Mounting Kit
The FieldLogger's HMI (Human-Machine Interface) can be assembled remotely to the equipment, being connected to it via a cable. This kit makes such operation easy, for it supplies all parts necessary to attach the HMI to a panel, connecting it to the FieldLogger to read the interested data.
- 8 universal analog input channels:
Thermocouples, V, mV, mA, Pt100 and Pt1000
Reading and logging rates of up to 1000/second
24-bit A/D conversion resolution
- 8 digital I/Os (individually configured as input or output)
- 2 relay outputs (NO, NC and common)
- RS485 interface (Modbus master or slave)
When acting as a master, can read up to 64 registers from other slaves
Registers read can be used in logging, alarms, or mathematical operations
- Ethernet interface with a lot of services available:
Sends alarm warning e-mails (SMTP)
Provides web pages with channels and status information (HTTP);
Allows logged data download via FTP (client and server)
Accesses status and channels values through network management software (SNMP and traps)
Allows Modbus communication by ethernet interface (Modbus TCP)
- USB-device interface for configuring, monitoring and download
- USB-host interface for logged data retrieval through a USB flash drive
- Up to 32 configurable alarms:
Alarm actions can include: activating relays, activating digital outputs, emails sending to multiple receivers, sending SNMP traps, starting and/or stopping logging.
- Up to 128 virtual channels:
- Basic mathematical functions to be applied on other channels: sum, subtraction, multiplication, division, logic (AND, OR and exclusive OR), square root, and power
- Auxiliar power supply 24 Vdc for up to eight 4-20 mA transmitters
- Power Supply
AC power (100 to 240 Vac)
DC Power (12 to 30 Vdc) optional (2011)
- Detachable human-machine interface (optional)
Keypad and color TFT QVGA display
RS485 communication with FieldLogger
- Loggings:
Up to 100 channels can be logged at a configurable rate
Data download through the configuration software or through the freely distributed download DLL
- UL and CE compliant
8/26/2024
Software and firmware upgrades benefit complex applications and more...
5/2/2024
NOVUS Automation solutions in the spotlight
3/20/2024
Use the code for free entry
9/27/2023
Solutions for the future of the Oil and Gas Industry
9/18/2023
The update allows more accurate flow measurement
6/5/2023
New devices dedicated to the energy sector
3/22/2023
8/18/2022
12/20/2021
Designed for the modernization and digitalization of the electric power industry, the 13th Latin-American Smart Grid Forum has NOVUS as a sponsor and exhibitor. The event, held on November 29th and 30th, gathered authorities, executives, managers, and engineers from electric power utilities and distributors from countries such as Brazil, Chile, and Colombia.
12/1/2021
Aderbal Lima, founding partner, CEO of NOVUS for 38 years and current board member of the company, participated in a business mission to Dubai in the second half of November. Lima attended the event as a representative and president of the Foreign Trade Council of FIERGS (Federation of Industries of the State of Rio Grande do Sul, Brazil). The activities at Expo Dubai serve to create networking between entrepreneurs and investors. In addition, it was also possible to visit startups and the information technology industrial center.
11/16/2021
The 13th edition of the Smart Grid Forum takes place on November 29th and 30th in São Paulo, at the Frei Caneca Convention Center. In addition to participating in the exhibition, NOVUS supports the initiative as a sponsor in this edition that has the theme "Accelerating energy digitalization and sector modernization in Brazil and Latin America".
10/27/2021
At NOVUS, we consider it essential for relationships to be respectful, which is why the organizational climate is one of the pillars of our strategic planning. It is in our DNA to act with ethics, balance, and integrity, conducting business with transparency and seeking sustainable and profitable socio-economic growth.
5/7/2021
1/15/2021
NOVUS sales success, FieldLogger is one of the most versatile options for data logging on the market.
7/29/2020
You can watch them in NOVUS YouTube Channel as many times as you want, and without time zone differences
11/6/2019
The conservation of historical documents and work of arts is one of the most important ways of cultural preservation. However, paintings should be protected from humidity, which can damage centenarian work of arts. Two pinacothecas of Porto Alegre City Hall have NOVUS solutions to ensure that their collections remain undamaged.
10/3/2019
96% of all financial transactions are made electronically whose records are stored in large data centers. The circulation of people in these places must be kept to a minimum as they contain sensitive information for the safety of customers. Since 2014, a Brazilian bank has been using NOVUS products with this purpose, putting together a solution consisting of an AirGate Modbus, a RHT-Air and a FieldLogger, with excellent results.
9/3/2019
It is very difficult to find processes that are not being monitored electronically nowadays. Whether to avoid human error, to meet regulatory requirements or even to reduce costs, the vast majority of companies have already dropped outdated clipboard notes and adopted data logging and monitoring equipment. In order to help choosing the most appropriate device to each process, this article discuss the characteristics of different electronic equipment for monitoring.
8/14/2019
Fieldlogger was the chosen solution to measure temperature and vibration of lift pumps at several wastewater treatment plants in São Paulo state. With proper monitoring, it is possible to prevent problems and save on engine maintenance.
6/17/2019
Cloud computing technologies are already a consolidated reality in the market. However, many people still keep prejudice in order to embrace this technology in business world, despite using it in a daily basis in their private life. The purpose of this article is to elucidate facts and myths about this technology and to facilitate the decision whether or not to deploy cloud oversight systems in your company.
2/7/2019
Attending DistribuTECH, an event focused on the energetic market, Fábio Pfeiffer says that the use of new technologies is already a reality but there is still a lot to do in this conservative segment.
9/5/2018
A pharmaceutical company located in Barueri, in the São Paulo metropolitan area, presented a challenge to NOVUS: implement a monitoring system in its new facilities, without causing changes in infrastructure. The main objective of the company was to obtain the release of the laboratory from the regulators for the production of the formulas, so that the assembled system should be validated.
1/11/2016
1.1 Objective: To use the AirGate-3G router to access HTTP service (pages in dynamics HTTP) hosted on the NOVUS FieldLogger equipment.