Humidity & Temperature

Home » Products » Sensing, Conditioning & Transmitters » Humidity & Temperature » Rht-p10 And Rht-xs Transmitters: Precise Measurement

01 - ISO 900102 - Reach Compliance03 - RoHS06 - CE11 - Ensured Accuracy17 - SigNow

RHT-P10 & RHT-XS


Temperature and Humidity Transmitter

The RHT-P10 and RHT-XS transmitters have highly accurate and stable sensors for measuring relative humidity and temperature. The measured values are converted into 4 to 20 mA output signals that are linearly related to their readings. Since they are microprocessor-based devices, they can be configured using the TxConfig-USB communication interface and the SigNow app or software, which is available for Android and Windows. The outputs can be configured to retransmit temperature, relative humidity, or dew point. 

 

The RHT-P10 model is suitable for monitoring temperature and relative humidity in pressurized environments and vacuum chambers. The sensor module has a metal body with a thread, suitable for fixing to a flange. The model is suitable for applications where the sensor module needs to be separate from the electronic module, but in the same pressure environment. 
 
* The flange for RHT-P10 is not included with the transmitter and must be purchased separately.



Still, unsure? Ask an expert! Make a Suggestion See all models Keep me updated

• Sensor Measuring Range:

Temperature: -40 to 120 °C  (-40 to 248 °F)
 Relative Humidity:

0 to 100 % RH (non-condensing)
 Dew Point:

-100 to 103 °C (-148 to 217.4 °F)
 Response time:

Temperature: up to 30s @ 25 °C (77 °F) (with air moving at 1 m/s or 3.28 ft/s), Humidity: up to 8s @ 25 °C (77 °F) (with air moving at 1 m/s or 3.28 ft/s)
 Measurement accuracy:

Temperature: ± 0.4 °C @ 25 °C (± 0.9 °F @ 77 °F), Relative Humidity: ± 3 % RH @ 25 °C (77 °F)
 Analog outputs:

4 to 20 mA or 20 to 4 mA, 2-wire type, loop-powered (current output versions), or 0 to 10 V (voltage output versions)
 Resolution of analog outputs:

0.0008 mA or 0.003 V
 Operating temperature:

-10 to 65 °C (14 to 149 °F), 0 to 95 % RH (electronic module)
 Connections:

Internal terminal blocks, via cable glands
 Sensor Cable Extension:

3 m (9.84 ft)
 Materials:

Housing (P10/XS models) in PA-GF, remote sensor module in SS316 (P10 models) or PA-GF (XS models)
 Degree of Protection:

Housing: IP65, sensor capsule: IP40
 Configuration:

SigNow software for Windows or Android via the TxConfig-USB configuration interface
 Certifications:

CE Mark

 

 