DigiRail Connect - Ethernet I/O Module

» » » » Digirail Connect - Ethernet I/o Module
CEConflict Mineral FreeISO 9001Reach ComplainceRoHS

DigiRail Connect


Ethernet I/O Module

DigiRail Connect is a versatile I/O module to be used as an extension of any brand automation system. Its rich mixed inputs and outputs offer industrial standard analog and digital signaling. The available DigiRail Connect options ensure the choice of suitable configuration for the customer application.

 

Bringing the Industry 4.0 to the rail level, the connectivity of DigiRail connect allows it to be used as slave Modbus RTU device in RS485 networks or as a server Modbus TCP device under Ethernet network.

 

Specially designed for harsh environments, DigiRail Connect complies with the main EMC and EMI standards, providing robustness and reliability for industrial applications.



Still, unsure? Ask an expert! Make a Suggestion See all models

- Inputs:
  RAMIX: 4 digital and 2 analog (isolated)
  DMIX: 8 digital

 

- Outputs:
  RAMIX: 3 digital or 2 relay and 2 analog (isolated)
  DMIX: 4 relays or 8 digital

 

- Analog signals:
  Thermocouples J, K, T, N, E, R, S and B
  Pt100, Pt1000, NTC,
  0-60 mV, 0-5 V, 0-10 V, 0-20 mA, 4-20 mA

 

- Analog input impedance:
  0-60 mV, Pt100, Pt1000, NTC and thermocouples: >10 MΩ
  0-5 V, 0-10 V: >1 MΩ
  4-20 mA: 15 Ω + (1 V @ 20 mA)

 

- Digital Input characteristics:
  Logical level "0": < 0.5 V
  Logical level "1": > 3 V
  Maximum voltage: 30 V
  Input impedance:270 kΩ
  Input current: @ 30 Vdc (typical) 0.15 mA
  Maximum frequency (square wave):
  Dry contact: 10 Hz
  PNP: 250 Hz
  NPN: 250 kHz

 

- Digital Output characteristics:
  Maximum load current: 500 mA
  Short circuit current: 200 mA
  Maximum switching voltage: 30 Vdc
  Minimum switching voltage: 6 Vdc

 

- Relay Output characteristics:
  Type: SPST-NO and SPDT
  Maximum load current: 3 A (SPST) / 6 A (SPDT)
  Switching voltage: 250 Vac
  Suitable for resistive loads

 

- Analog Output characteristics:
  Signal types: 0-20 mA, 4-20 mA, 0-10 V
  Maximum load: 0-20 / 4-20 mA: ≤ 500 Ω
  0-10 V: ≥ 2000 Ω

 

- Analog Channel resolution:
  Analog inputs: 16 bits (65000 levels)
  Analog outputs: 12 bits

 

- Communication interface:
  USB
  Ethernet: 10/100 Mb/s, IEEE standard 802.3u
  RS485

 

- Software:
  NXperience (via USB)

 

- Power Supply:
  Voltage: 10 Vdc to 36 Vdc
  Maximum Consumption: 5 W
  Typical Consumption: 20 mA

 

- Operating conditions:
  Temperature: -20 to 60°C ( -4 to 140°F)
  Humidity: 5 to 95% RH, non-condensing

 

- Enclosure: ABS+PC

 

 

 

 

 

 

 

 

10/10/2019

Ethernet IO Module DigiRail Connect - Commercial Flyer

Download - Ethernet IO Module DigiRail Connect - Commercial Flyer

Selecione a Opção Desejada

Save

(PDF - 1.00 Mb)

3/8/2021

Operating Manual DigiRail Connect

Download - Operating Manual DigiRail Connect

Selecione a Opção Desejada

Save

(PDF - 2.25 Mb)

7/15/2021

DigiRail Connect firmware update V1.03 (7/15/2021)

DigiRail Connect firmware update.

Download - DigiRail Connect firmware update V1.03 (7/15/2021)

Selecione a Opção Desejada

Save

(ZIP - 0.27 Mb)

12/17/2019

RS485 & RS422 Basics

Important topics for the design, analysis and installation of communication networks using an RS485 or RS422 bus.

Download - RS485 & RS422 Basics

Selecione a Opção Desejada

Save

(PDF - 1.03 Mb)

12/9/2019

Q&A Webinar DigiRail Connect

Download - Q&A Webinar DigiRail Connect

Selecione a Opção Desejada

Save

(PDF - 0.17 Mb)

8/3/2021

UKCA - D.O.C. DigiRail Connect and DigiRail NXprog

UKCA Declaration of Conformity.

Download - UKCA - D.O.C. DigiRail Connect and DigiRail NXprog

Selecione a Opção Desejada

Save

(PDF - 0.19 Mb)

3/8/2021

CE - D.O.C. DigiRail Connect and DigiRail NXprog

CE Declaration of Conformity.

Download - CE - D.O.C. DigiRail Connect and DigiRail NXprog

Selecione a Opção Desejada

Save

(PDF - 0.19 Mb)

  • SuperView - Process Supervision Software SCADA

    SuperView is a Supervisory Control and Data Acquisition software (SCADA) that brings to the user a visual development model to create applications. Besides communication with Modbus RTU and Modbus TCP devices, also is posible to use SuperView stations operating in Client or Server modes allowing distributed supervision of a process or system.


    The user can use different kinds of resources that simplify the configuration, bringing flexibility to take decisions when developing the synoptic. Customized access policies for...

  • SuperView Mobile - SCADA Application for Mobile Supervision

    SuperView Mobile is a SCADA (Supervisory Control And Data Acquisition) system developed for users who want to monitor, control and supervise devices in their industrial, commercial or residential plant using Android Smartphones and Tablets. This mobile system provides an easy interface use for advanced users and beginners, in addition to providing a configuration wizard that guides the user to develop a complete application.

     

    Remote communication is carried out using the Modbus TCP protocol over the communication interf...

10/10/2019

Ethernet IO Module DigiRail Connect - Commercial Flyer

Download - Ethernet IO Module DigiRail Connect - Commercial Flyer

Selecione a Opção Desejada

Save

(PDF - 1.00 Mb)

3/8/2021

Operating Manual DigiRail Connect

Download - Operating Manual DigiRail Connect

Selecione a Opção Desejada

Save

(PDF - 2.25 Mb)

7/15/2021

DigiRail Connect firmware update V1.03 (7/15/2021)

DigiRail Connect firmware update.

Download - DigiRail Connect firmware update V1.03 (7/15/2021)

Selecione a Opção Desejada

Save

(ZIP - 0.27 Mb)

12/17/2019

RS485 & RS422 Basics

Important topics for the design, analysis and installation of communication networks using an RS485 or RS422 bus.

Download - RS485 & RS422 Basics

Selecione a Opção Desejada

Save

(PDF - 1.03 Mb)

12/9/2019

Q&A Webinar DigiRail Connect

Download - Q&A Webinar DigiRail Connect

Selecione a Opção Desejada

Save

(PDF - 0.17 Mb)

8/3/2021

UKCA - D.O.C. DigiRail Connect and DigiRail NXprog

UKCA Declaration of Conformity.

Download - UKCA - D.O.C. DigiRail Connect and DigiRail NXprog

Selecione a Opção Desejada

Save

(PDF - 0.19 Mb)

3/8/2021

CE - D.O.C. DigiRail Connect and DigiRail NXprog

CE Declaration of Conformity.

Download - CE - D.O.C. DigiRail Connect and DigiRail NXprog

Selecione a Opção Desejada

Save

(PDF - 0.19 Mb)

  • 8811611440

    DigiRail Connect (RAMIX 2AI / 2AO / 4DI / 2RL ETH)

  • 8811611420

    DigiRail Connect (RAMIX 2AI / 2AO / 4DI / 3DO ETH)

  • 8811612440

    DigiRail Connect (DMIX 8DI / 4RL ETH)

  • 8811612420

    DigiRail Connect (DMIX 8DI / 8DO ETH)

Related News

Share: