I/O module for IoT application DigiRail OEE

Home » Products » Data Acquisition & Communication » I/o Modules » I/o Module For Iot Application Digirail Oee

ANATELCEConflict Mineral FreeFCCReach ComplainceRoHS

DigiRail OEE


I/O module for IoT application

DigiRail OEE is an I/O module for IoT application designed for OEE (Overall Equipment Effectiveness) and MES (Manufacturing Execution System) industrial systems.

 

It has the main industrial approvals, in order to ensure monitoring reliability in harsh environments. Its internal memory buffer capability grants data retention and integrity in an eventual downlink, keeping the data logging seamlessly. Provided with secure MQTT protocol, DigiRail OEE transmits data natively to Google Cloud, Microsoft Azure, Amazon AWS, NOVUS Cloud, or any other compatible IoT cloud platform.

 

The configuration software NXperience provides a user-friendly configuration interface, allowing input simulation and output forcing, locally through USB port and remotely through Modbus TCP. System diagnosis and maintenance become very easy thanks to the remote configuration and functions viewing. DigiRail OEE allows to send MQTT and Modbus TCP commands to read status and to set device parameters.

 



Still, unsure? Ask an expert! Make a Suggestion See all models

- Inputs:
  6 digital
  2 analog

- Outputs:
  2 digital

- Analog signals:
  0-5 V, 0-10 V, 0-20 mA and 4-20 mA

- Digital signals:
  NPN, PNP and dry contact

- Analog input impedance:
  mA: 15 Ω + 1.5 V
  V: 1 MΩ

- Digital input features:
  Logical level "0": <0.5 V
  Logical level "1": > 3 V
  Maximum voltage: 30 V
  Input impedance: 270 kΩ
  Input current: @ 30 Vdc (typical) 0.15 mA
  Maximum frequency (square wave):
  Dry contact: 10 Hz
  PNP: 3 kHz
  NPN: 3 kHz
  Minimum pulse duration:
  Dry contact: 50 ms
  PNP: 150 us
  NPN: 150 us

- Digital output characteristics:
  2 NPN digital outputs 
  Maximum current that can switch the output: 700 mA

- Analog channel resolution:
  Analog inputs: 15 bits (32000 levels)

- Communication interface:
  USB
  Ethernet: 10/100 Mb / s, IEEE standard 802.3u
  Wi-Fi 802.11 b / g / n 2.4 GHz
  RS485

- Software:
  NXperience

- Power supply:
  Voltage: 10 Vdc to 36 Vdc
  Wi-Fi model:
  Typical consumption: 70 mA @ 24V
  Maximum consumption: 160 mA @ 12V
  Ethernet model:
  Typical consumption: 50 mA @ 24V
  Maximum consumption: 120 mA @ 12V

- Operation conditions:
  Temperature:
 -20 to 60 ° C (-4 to 140 ° F)
  Humidity:
  5 to 95% RH, non-condensing

- Battery:
  CR2032 for internal clock retention

- Assembly:
  DIN rail or screw mounting.

- Degree of Protection
  IP20

- Enclosure:
  ABS + PC

 


        
        
        
        
10/5/2021

DataSheet DigiRail OEE

Download - DataSheet DigiRail OEE

Selecione a Opção Desejada

Save

(PDF - 0.77 Mb)

7/19/2021

Operating Manual DigiRail OEE (V1.1x B)

Recommended for devices with firmware version V 1.1x and higher.

Download - Operating Manual DigiRail OEE (V1.1x B)

Selecione a Opção Desejada

Save

(PDF - 2.99 Mb)

6/15/2021

Modbus-TCP Protocol

Recommended for devices with firmware version V 1.1x and higher.

Download - Modbus-TCP Protocol

Selecione a Opção Desejada

Save

(PDF - 0.47 Mb)

5/7/2021

MQTT Protocol

Recommended for devices with firmware version V 1.1x and higher.

Download - MQTT Protocol

Selecione a Opção Desejada

Save

(PDF - 0.36 Mb)

6/7/2021

Operating Manual DigiRail OEE (V1.0x I)

Recommended for devices with firmware version up to V 1.0x.

Download - Operating Manual DigiRail OEE (V1.0x I)

Selecione a Opção Desejada

Save

(PDF - 3.05 Mb)

7/19/2021

Firmware update Ethernet model V1.12 (7/19/2021)

DigiRail OEE firmware update (ETH).

Download - Firmware update Ethernet model V1.12 (7/19/2021)

Selecione a Opção Desejada

Save

(ZIP - 0.70 Mb)

7/19/2021

Firmware update WiFi model V1.12 (7/19/2021)

DigiRail OEE firmware update (WiFi).

Download - Firmware update WiFi model V1.12 (7/19/2021)

Selecione a Opção Desejada

Save

(ZIP - 0.72 Mb)

8/2/2021

CE - D.O.C. DigiRail OEE

CE Declaration of Conformidity.

Download - CE - D.O.C. DigiRail OEE

Selecione a Opção Desejada

Save

(PDF - 0.17 Mb)

  • NOVUS Cloud - Cloud IoT Platform

    NOVUS Cloud is an IoT platform solution for monitoring devices for process data online visualization. Ready-to-use with NOVUS smart IoT devices, it is the perfect choice for customers with low IT infrastructure or with requirements of unified data from multiple devices at multiple locations.


    NOVUS Cloud can receive information of any kind from the IoT devices, store them in the cloud database and present the data in nice and elegant dashboards.


    Operation or management staff c...

    11/5/2020 - Instruction Manual NOVUS Cloud

  • NXperience Trust - Configuration, Data Collection and Analysis Software

    NXperience Trust is validating software specially designed for the pharmaceutical, food and health market segments for the configuration and data collection of data loggers for the environment variables to be monitored. These segments require a reliable, simple and intuitive system to use, as complete data analysis and visualization, user authentication, and information security features.

     

    The NXperience Trust connectivity allows it to be used as a central data management tool, and can handle infor...

    11/9/2021 - NXperience Installer V2.1.8.11 (11/9/2021)

10/5/2021

DataSheet DigiRail OEE

Download - DataSheet DigiRail OEE

Selecione a Opção Desejada

Save

(PDF - 0.77 Mb)

7/19/2021

Operating Manual DigiRail OEE (V1.1x B)

Recommended for devices with firmware version V 1.1x and higher.

Download - Operating Manual DigiRail OEE (V1.1x B)

Selecione a Opção Desejada

Save

(PDF - 2.99 Mb)

6/15/2021

Modbus-TCP Protocol

Recommended for devices with firmware version V 1.1x and higher.

Download - Modbus-TCP Protocol

Selecione a Opção Desejada

Save

(PDF - 0.47 Mb)

5/7/2021

MQTT Protocol

Recommended for devices with firmware version V 1.1x and higher.

Download - MQTT Protocol

Selecione a Opção Desejada

Save

(PDF - 0.36 Mb)

6/7/2021

Operating Manual DigiRail OEE (V1.0x I)

Recommended for devices with firmware version up to V 1.0x.

Download - Operating Manual DigiRail OEE (V1.0x I)

Selecione a Opção Desejada

Save

(PDF - 3.05 Mb)

7/19/2021

Firmware update Ethernet model V1.12 (7/19/2021)

DigiRail OEE firmware update (ETH).

Download - Firmware update Ethernet model V1.12 (7/19/2021)

Selecione a Opção Desejada

Save

(ZIP - 0.70 Mb)

7/19/2021

Firmware update WiFi model V1.12 (7/19/2021)

DigiRail OEE firmware update (WiFi).

Download - Firmware update WiFi model V1.12 (7/19/2021)

Selecione a Opção Desejada

Save

(ZIP - 0.72 Mb)

8/2/2021

CE - D.O.C. DigiRail OEE

CE Declaration of Conformidity.

Download - CE - D.O.C. DigiRail OEE

Selecione a Opção Desejada

Save

(PDF - 0.17 Mb)

  • 8811814420

    DIGIRAIL OEE 2AI / 6DI / 2DO ETH

  • 8811814460

    DIGIRAIL OEE 2AI / 6DI / 2DO WIR

Related News

  • 12/10/2020

    NOVUS launches I/O module for OEE systems

    Every company is constantantly searching for efficiency, by optimizing resources and increasing productivity without sacrificing quality. The OEE (acronym for Overall Equipment Effectiveness) is an indicator used to measure performance in the industry. It is a value that points out how much the company uses its machines, labor and materials in production, helping to improve processes, identify losses and increase equipment productivity.

Share: