The N1500-LC Indicator is the ideal instrument for monitoring analogue variables in industrial processes with Load Cells.
The N1500 is compatible with the most popular signals from load cells such as 0 to 20 mV, -20 to 20 mV, 0 to 50 mV, 0 to 20 mA and 4 to 20 mA.
The indicator has programmable scale, configurable decimal point, supply of 10V dedicated for load cells, easy to read display, universal AC/DC power supply, options up to 4 alarm relays, 4 to 20 mA retransmission and RS485 serial port with MODBUS protocol.



Still, unsure? Ask an expert! Make a Suggestion See all models

- Input: 4-20 mA, 0-20 mA, 0-50 mV, 0-20 mV and -20 to 20 mV
  Increasing or decreasing indication
  10 Vdc (or 5 Vdc) dedicated power supply for load cells
  Record of maximum and minimum values
  Hold, peak hold, tare, zero tare and auto zero functions
  Digital input
- Optionally you can display:
  Retransmission of the PV to 0-20 mA or 4-20 mA
  RS485 serial communication with MODBUS RTU Protocol
  Third and fourth alarm relays
- Dimensions: 48 x 96 x 92 mm (1/16 DIN)
- Approximate Weight: 250 g
- Panel cut: 45 x 93 mm (+0.5 -0.0 mm)
- Universal switching power supply: 100 to 240 Vac / dc ± 10%, 50/60 Hz
- Optional Input: 24 Vac / dc ± 10%
- Maximum power consumption: 7.5 VA
- Environmental conditions:
  Operating Temperature: 5 to 50 ° C
  Relative Humidity: 80% to 30 ° C
  For temperatures higher than 30 ° C, decrease by 3% by ° C
  Intern use; Installation category II, Degree of pollution 2, Altitude <2000 m
- Input: Voltage and Current (configurable according to table 1)
- Internal Resolution: 128,000 levels
- Display resolution: 62,000 levels
- Sample rate: 15 samples per second
- Precision: 0.2% of span
- Input impedance: 0-50 mV> 10 MΩ, 0-20 mA, 4-20 mA: 15 Ω (+2 Vdc @ 20 mA)
- Auxiliary Voltage Source: 5 or 10 Vdc, ± 1%, 35 mA
- Electromagnetic compatibility: EN 61326-1: 1997 and EN61326-1 / A1: 1998
- Security: EN61010-1: 1993 and EN61010-1 / A2: 1995
- Ready for 6.3 mm connection terminals
- Front panel: Polycarbonate UL94 V-2
- Case: ABS + PC UL94 V-0

 

 

 

 


        
10/11/2020

Operating Manual N1500-LC

Download - Operating Manual N1500-LC

Selecione a Opção Desejada

Save

(PDF - 0.91 Mb)

7/21/2014

2D Housing Drawing - N1500

Download - 2D Housing Drawing - N1500

Selecione a Opção Desejada

Save

(ZIP - 0.37 Mb)

11/19/2020

N1500 Registers Table for MODBUS communication

Download - N1500 Registers Table for MODBUS communication

Selecione a Opção Desejada

Save

(PDF - 0.52 Mb)

11/19/2018

CE - D.O.C. N1500LC

CE Declaration of Conformidity.

Download - CE - D.O.C. N1500LC

Selecione a Opção Desejada

Save

(PDF - 0.15 Mb)

10/6/2020

QuickTune Configurator V1.0.0.01

Software for configuration of N1020, N1040, N1040T, N1050, N1100, N480D, N120, N1200, N1200HC, N2000, N960, N3000 controllers and N1040i, N1540, N1500 and N1500LC indicators.

Download - QuickTune Configurator V1.0.0.01

Selecione a Opção Desejada

Save

(ZIP - 13.01 Mb)

  • 81500LC410

    N1500-LC Load Cell Indicator, 2 relays + 4-20 mA, 96x48 mm

  • 81500LC430

    N1500-LC Load Cell Indicator w/ 4-20mA analog out + RS485 + 4 relays 96x48 mm

  • 81500LC430

    N1500-LC RS485 Load Cell Indic. 4 relays + 4-20 mA, 96x48 mm

  • 81500LC434

    N1500-LC RS485 24V Load Cell Indic. 4 relays, 4-20mA 96x48 mm

  • 8830005000

    PT100 STAINLESS STEEL 304 5X30MM CABLE PVC 1,5M 100C

  • 8830015615

    THERMOCOUPLE J PROBE 6X7MM W / SPRING BAIONET SM CONNECTION CABLE FB+FB+SS BRAIDING INSULATED 1,5M 300C

  • 8830016631

    THERMOCOUPLE K HANDLE AND CAB. PVC 2MT W/ CONECTOR MINI, 100C

  • 8806060410

    TxMini-M12-MP (TxMini-M124-20mA + stainless steel case 6x100mm + female conector, 1M cable)

  • 8830007700

    PT100 PVC ½ NPT 6X100MM 200C

  • 8830007000

    PT100 STAINLESS STEEL 316 6x50MM ½ BSP CAB LARGE 300C

  • 8830015625

    THERMOCOUPLE J PROBE 6X7MM W / SPRING BAIONET SM CONNECTION CABLE FB+FB+SS BRAIDING INSULATED 2,5M 300C

  • 8806060425

    TxMini-M12-RS485-MP (TxMini-M12-RS485+ stainless steel case 6x100mm + female conector, 1m cable)

  • 8830007750

    PT100 3 STAINLESS STEEL 316 WIRE ½ BSP 6X100MM CABLE 2M PVC 200C

  • 8830007010

    PT100 STAINLESS STEEL 316 6X100MM ½ BSP CAB LARGE 300C

  • 8830015815

    THERMOCOUPLE J PROBE 9X7MM W/SPRING BAIONET LARGE CABLE FB+FB+SS BRAIDING INSULATED 3M 300C

  • 8830007800

    PT100 SILICON 2M ½ BSP STEM 6X100MM, 200C

  • 8830015830

    THERMOCOUPLE J PROBE 8X7MM W/SPRING BAIONET LARGE CABLE FB+FB+SS BRAIDING INSULATED 3M 300C

  • 8830007150

    PT100 STAINLESS STEEL 316 6X150MM ½ BSP CAB LARGE 300C

  • 8830015845

    THERMOCOUPLE J PROBE 8X7MM W/SPRING BAIONET LARGE 18MM + ADAPT 4,5M DIAM 8MM, 300C

  • 8830007450

    PT100 PROBE 6X23MM BAIONET SPRING LARGE CABLE FB+FB+SS BRAIDING INSULATED 1,5M 300C

  • 8830007200

    PT100 STAINLESS STEEL 316 6X100MM ½ NPT CAB LARGE 300C

  • 8830007250

    PT100 STAINLESS STEEL 316 6X200MM ½ BSP CAB LARGE 300C

  • 8830007350

    PT100 STAINLESS STEEL 316 6X300MM ½ BSP CAB LARGE 300C

  • 8830007352

    PT100 STAINLESS STEEL 316 6X300M ½ NPT CAB. LARGE 300C

Share:

NOVUS Global Privacy Notice

NOVUS is committed to protect the privacy and security of your personal information. The data that you share with NOVUS allows us to provide a better experience when you use our products and services. We guarantee total privacy to your data, used exclusively for communications between NOVUS and you.

In this statement we affirm:

  1. NOVUS does not sell or negotiate customer information;
  2. Your data are stored in secure and controlled environment;
  3. We use your data only for communications of your interest;
  4. At any time you may opt out of the list;

Please see our complete Privacy Policy

After read our Privacy Policy, chose the option bellow: