N1500 - Universal process indicator

» » » » N1500 - Universal Process Indicator
CEConflict Mineral FreeRoHSUL

N1500


Universal process indicator

N1500 universal process indicator works at fast sampling rate, which ensures high-performance indication and reaction to fast processes dynamics. With 6 digits for high-resolution variables and the 17mm height display, N1500 provides clear view, making it easier for operators to read and diagnose from a distance.


Its timer function performs wide action capabilities through alarms for safety interlock logic. Furthermore, N1500 is fully compatible with custom signals through its linearized input for up to 30 points.
Both electronic robustness and anti-flame material enclosure comply with the main world-class approvals for industry devices.



Still, unsure? Ask an expert! Make a Suggestion See all models

- Display: 7-segment LED, 6-digit with 17 mm height
- Input Type: Thermocouples J, K, T, N, R, S, B, E, Pt100, 0-20 mA, 4-20 mA, 0 -50 mV, 0-5 Vdc, 0-10 Vdc, 4-20 mA no linear, 0-20 mA custom linear, 4-20 mA custom linear, 0-20 mA custom no linear, 4-20 mA custom no linear.
- Accuracy: Thermocouples J, K, T: 0.25% of span ± 1 ° C; Thermocouples N, R, S, B: 0.25% of span ± 3 ° C; Pt100, 0-20 mA, 4-20 mA, 0- 5 Vdc, 0-10 Vdc: 0.2% of the span
- Sampling Rate: 5 samples per second for Pt100 and Thermocouples; 15 samples per second for 0-50 mV, 4-20 mA, 0-5 V and 0-10 V
- Display Resolution: Temperature: 1 / 0.1; Other measures: 1 / 0.1 / 0.01 / 0.001 / 0.0001
- Custom Linearization: 30 points for non-standard sensors
- Digital Input: Operates as a key for Hold, Peak Hold and maximum/minimum reset.
- Analog Output: 0-20 mA or 4-20 mA (optional) - electrically isolated
- Alarms: Up to 4 alarms
- Alarm Types: Minimum, maximum, minimum differential, maximum differential, differential out of range, differential within range, and open sensor.
- Timer Function: Alarms with delay, pulse, or oscillator timing.
- Auxiliary Power Supply: 24 Vdc
- Optional: 2 relays, analog output (4-20 mA or 0-20 mA), RS485
- Communication: RS485 Modbus RTU optional
- Math Function: Square Root
- Safety: Password protected configuration
- Configuration Interface: Via RS485
- Power Supply: 100-240 Vac / dc or 12-24 Vdc 
- Maximum Consumption: 7.5 VA
- Dimensions: 96 x 48 x 92 mm (1/8 DIN)
- Front Panel: IP65; Polycarbonate (PC) UL94 V-2
- Enclosure: IP20; ABS + PC UL94 V-0
- Operating Conditions: 5 to 50 ° C, and 0 to 80% RH up to 30 °C
- Aprovals: CE, UL and cUL


        
8/19/2020

Universal Process Indicator N1500 - Flyer

Download - Universal Process Indicator N1500 - Flyer

Selecione a Opção Desejada

Save

(PDF - 1.13 Mb)

3/22/2021

Operating Manual N1500

Download - Operating Manual N1500

Selecione a Opção Desejada

Save

(PDF - 0.96 Mb)

11/19/2020

N1500 Registers Table for MODBUS communication

Download - N1500 Registers Table for MODBUS communication

Selecione a Opção Desejada

Save

(PDF - 0.52 Mb)

4/23/2021

CE - D.O.C. N1500

CE Declaration of Conformidity.

Download - CE - D.O.C. N1500

Selecione a Opção Desejada

Save

(PDF - 0.17 Mb)

4/23/2021

UKCA - D.O.C. N1500

UKCA Declaration of Conformidity.

Download - UKCA - D.O.C. N1500

Selecione a Opção Desejada

Save

(PDF - 0.17 Mb)

7/21/2014

2D Housing Drawing - N1500

Download - 2D Housing Drawing - N1500

Selecione a Opção Desejada

Save

(ZIP - 0.37 Mb)

  • QuickTune - Configuration Software to controllers and indicators

    QuickTune is a free software tool for parameter configuration of NOVUS controllers and indicators. With its clean interface, any lay or advanced user can friendly access and modify all device functions for proper configuration. Designed for easy and quick commissioning, it provides diagnosis and monitoring resources to field technicians. More than a software, QuickTune is a tool. Furthermore, QuickTune offers the main features to meet most users and profile needs in the industry.

    ...

    7/23/2021 - QuickTune Configurator V1.0.6.00

  • SuperView - Process Supervision Software SCADA

    SuperView is a Supervisory Control and Data Acquisition software (SCADA) that brings to the user a visual development model to create applications. Besides communication with Modbus RTU and Modbus TCP devices, also is posible to use SuperView stations operating in Client or Server modes allowing distributed supervision of a process or system.


    The user can use different kinds of resources that simplify the configuration, bringing flexibility to take decisions when developing the synoptic. Customized access policies for...

  • SuperView Mobile - SCADA Application for Mobile Supervision

    SuperView Mobile is a SCADA (Supervisory Control And Data Acquisition) system developed for users who want to monitor, control and supervise devices in their industrial, commercial or residential plant using Android Smartphones and Tablets. This mobile system provides an easy interface use for advanced users and beginners, in addition to providing a configuration wizard that guides the user to develop a complete application.

     

    Remote communication is carried out using the Modbus TCP protocol over the communication interf...

  • FieldChart - Supervisory and Data Acquisition Software

    FieldChart is a software used for monitor and register data acquired from NOVUS products. It generates real time trends and data lists that can be exported in usable formats like a spread sheet. There are two versions available: FieldChart-Lite and FieldChart-64C.

     

     

    The FieldChart-Lite can register 8 simultaneous channels and it is available for free.

     

     

    The FieldC...

    7/30/2021 - FieldChart-Lite V2.0.3.06

  • 8150000020

    N1500 Universal Indicator, 2 relays, 96x48 mm

  • 8150000024

    N1500 24V Universal Indicator, 2 relays, 96x48 mm

  • 8150000040

    N1500 Universal Indicator 4 relays, 96x48 mm

  • 8150000100

    N1500 Universal Indicator, 2 relays + 4-20 mA, 96x48 mm

  • 8150000230

    N1500 RS485 Universal Indicator, 4 relays + 4-20 mA, 96x48mm

  • 8150000234

    N1500 RS485 24V Univ. Indicator, 4 relays + 4-20 mA, 96x48mm

  • 8830016631

    THERMOCOUPLE K HANDLE AND CAB. PVC 2MT W/ CONECTOR MINI, 100C

  • 8806060410

    TxMini-M12-MP (TxMini-M124-20mA + stainless steel case 6x100mm + female conector, 1M cable)

  • 8830007700

    PT100 PVC ½ NPT 6X100MM 200C

  • 8830015625

    THERMOCOUPLE J PROBE 6X7MM W / SPRING BAIONET SM CONNECTION CABLE FB+FB+SS BRAIDING INSULATED 2,5M 300C

  • 8806060425

    TxMini-M12-RS485-MP (TxMini-M12-RS485+ stainless steel case 6x100mm + female conector, 1m cable)

  • 8830007750

    PT100 3 STAINLESS STEEL 316 WIRE ½ BSP 6X100MM CABLE 2M PVC 200C

  • 8830007010

    PT100 STAINLESS STEEL 316 6X100MM ½ BSP CAB LARGE 300C

  • 8830007800

    PT100 SILICON 2M ½ BSP STEM 6X100MM, 200C

  • 8830007150

    PT100 STAINLESS STEEL 316 6X150MM ½ BSP CAB LARGE 300C

  • 8830007200

    PT100 STAINLESS STEEL 316 6X100MM ½ NPT CAB LARGE 300C

  • 8830007350

    PT100 STAINLESS STEEL 316 6X300MM ½ BSP CAB LARGE 300C

  • 8830007352

    PT100 STAINLESS STEEL 316 6X300M ½ NPT CAB. LARGE 300C

Share: