LogBox-AA - Micro Data Logger for Analog Signals

» » » Logbox-aa - Micro Data Logger For Analog Signals
  • Visualizar imagens do produto LogBox-AA
  • Visualizar imagens do produto LogBox-AA

LogBox-AA is an electronic data logger with two input analog channels. Input data is stored in the logger internal memory, for later download to a PC for visualization and analysis in the form of tables or graphs. The data is easily exported to spreadsheets.
The LogChart-II is the software used to configure the logger, download and visualize data. The logger configuration allows defining the logger operation mode, including programming the start/stop time of data acquisition. Other parameters such as signal input type, logging interval, etc, are easily selected through the LogChart-II software.
The LogBox-AA also provides a signal for commanding an external power supply (battery) of a device connected to the logger. This feature allows that external devices, such as a transmitter, be powered only during the measurement sample time, thus extending the autonomy of these external batteries.



      
  • Input: 0-20 mA, 4-20 mA, 0-50 mV and 0-10 Vdc
        

            
    • J range: -50 to 760 °C (-58 to 1400 ºF)

    •       
    • K range: -90 to 1370 °C (-130 to 2498 ºF)

    •       
    • T range: -100 to 400 °C (-148 to 752 ºF)

    •       
    • N range: -90 to 1300 °C (-130 to 2372 ºF)

    •       
    • R range: 0 to 1760 °C (32 to 3200 ºF)

    •       
    • S range: 0 to 1760 °C (32 to 3200 ºF)

    •       
    • B range: 150 to 1820 °C (32 to 3308 ºF)

    •       
    • Pt100 range: -200.0 to 650.0 °C (-328 to 1202 ºF)

    •     

      

  •   
  • Memory capacity: 32 k or 64 k readings

  •   
  • Interval between readings: 1 second to 18 hours

  •   
  • External battery switch time: 0 to 10 s

  •   
  • Power: Internal 3.6 V lithium battery (1/2 AA)

  •   
  • Estimated autonomy: 200 days with one weekly download and 5 minutes measuring interval. Battery life depends heavily on data retrieval frequency.

  •   
  • Working temperature: From –40 °C to 70 °C

  •   
  • Protection: IP65 and IP67 models (see lateral label on product)

  •   
  • Material: ABC + PC case, Polycarbonate film

  •   
  • Dimensions: 60 x 70 x 35 mm


        
        
        
        
        
        
        
  • 8813002000

    LogBox-AA-32k-IP65 Data logger IP65, 2 analog Input

  • 8813002010

    LogBox-AA-32k-IP67 Data logger IP67, 2 analog Input

  • 8813002001

    LogBox-AA-64k-IP65 Data logger IP65, 2 analog Input

  • 8813002011

    LogBox-AA-64k-IP67 Data logger IP67, 2 analog Input

  • Downloads

6/14/2019

Flyer LogBox-AA

Download - Flyer LogBox-AA

Selecione a Opção Desejada

Save

(PDF - 0.29 Mb)

6/26/2018

Operating Manual LogBox-AA

Download - Operating Manual LogBox-AA

Selecione a Opção Desejada

Save

(PDF - 1.47 Mb)

8/31/2016

LogChart II Installer - V2.6.8.00 (8/31/16)

This software is used for LogBox-RHT-LCD, LogBox-RHT, LogBox-DA, LogBox-AA, TagTemp data loggers, N120DL, TagTemp-USB and TagTemp Stick.

Download - LogChart II Installer - V2.6.8.00 (8/31/16)

Selecione a Opção Desejada

Save

(ZIP - 5.73 Mb)

2/11/2010

IR-Link 3 Driver (02/11/2010)

USB driver for the IrLink3 interface. Usage instructions: Unpack all files to a temporary folder, plug the IrLInk3 interface in a USB port. The Windows New Hardware Wizard will ask for a driver. Select the manual installation option and enter the path to the unpacked files. Follow the Wizard instructions to finish installation.

Download - IR-Link 3 Driver (02/11/2010)

Selecione a Opção Desejada

Save

(ZIP - 1.07 Mb)

10/14/2015

CE - D.O.C. LogBox-AA

CE Declaration of conformidity.

Download - CE - D.O.C. LogBox-AA

Selecione a Opção Desejada

Save

(PDF - 0.08 Mb)

Related News

  • Article: For each problem, a solution: the right choice for monitoring my process

    9/3/2019

    It is very difficult to find processes that are not being monitored electronically nowadays. Whether to avoid human error, to meet regulatory requirements or even to reduce costs, the vast majority of companies have already dropped outdated clipboard notes and adopted data logging and monitoring equipment. In order to help choosing the most appropriate device to each process, this article discuss the characteristics of different electronic equipment for monitoring.

Compartilhar:

NOVUS Global Privacy Notice

NOVUS is committed to protect the privacy and security of your personal information. The data that you share with NOVUS allows us to provide a better experience when you use our products and services. We guarantee total privacy to your data, used exclusively for communications between NOVUS and you.

In this statement we affirm:

  1. NOVUS does not sell or negotiate customer information;
  2. Your data are stored in secure and controlled environment;
  3. We use your data only for communications of your interest;
  4. At any time you may opt out of the list;

Please see our complete Privacy Policy

After read our Privacy Policy, chose the option bellow: