Portable Temperature Meters - N305 and N306 -

» » » Portable Temperature Meters - N305 And N306 -
  • Visualizar imagens do produto Portable Temperature Meters - N305 and N306

The portable thermometers models N305 and N306 accurately show in their high contrast LCD display the temperature being measured by the connected thermocouple sensor.
Model N305 has one sensor input (T1). Model N306 has two sensor inputs and buttons T1and T2 select the channel to be displayed. The temperature difference between the two sensors can also be shown.
Both models have Celsius or Fahrenheit selection and model N305 displays temperature with decimals.
Sensor error can be reduced or eliminated by means of a convenient recessed from panel offset adjustment.


      
  • Temperature indication unit: Celsius or Fahrenheit

  •   
  • Measurement Range:  -50 to 1300 °C (-58 to 2000 °F)

  •   
  • Resolution: 1 °C or 0,1 °F (Model N306); 0.1 °C or 0.1 °F (Model N305)

  •   
  • Accuracy is specified for operating temperatures over the range of 18 °C to 28 °C (64 °F to 82 °F), for 1 year, not including thermocouple error

  •   
  • Temperature Coefficient: 0.1 times the applicable accuracy specification per °C from 0 °C to 18 °C and 28 °C to 50 °C (32 °F to 64 °F and 82 °F to 122 °F)

  •   
  • Input Protection: 60 Vdc or 24 Vrms ac maximum input voltage on any combination of input pins

  •   
  • Reading Rate: 2.5 times per second

  •   
  • Ambient Operating Range: 0 °C to 50 °C (32 °F to 122 °F)

  •   
  • Storage Temperature:  -20 °C to 60 °C (-4 °F to 140 °F)

  •   
  • Relative Humidity: 0% to 80% (0 °C to 35 °C) (32 °F to 95 °F); 0% to 70% (35 °C to 50 °C) (95 °F to 122 °F)

  •   
  • Input Connector: Accepts standard miniature thermocouple connectors (flat blades spaced 7.9 mm, center to center)

  •   
  • High contrast 3½ digit LCD display

  •   
  • Mode: hold, máx, fine adjustment (offset) and  T1-T2

  •   
  • Battery: Standard 9 V battery (NEDA 1604, IEC 6F22)

  •   
  • Battery life: 200 hours typical with carbon zinc battery

  •   
  • Supplied Probe: 4-foot type “K” thermocouple bead probe (teflon insulated). Maximum insulation temperature 260 °C (500 °F)

  •   
  • Probe accuracy: ±2.2 °C or ±0.75 % of reading (whichever is greater) from 0 °C to 800 °C

  •   
  • Dimensions: 147 mm (H) x 70 mm (W) x 39 mm(D)

  •   
  • Weight: 210g (7.4 ounces)

  • Downloads

3/26/2010

Operating Manual N305 e N306

Download - Operating Manual N305 e N306

Selecione a Opção Desejada

Save

(PDF - 0.10 Mb)

7/30/2008

Flyer N305 e N306

Download - Flyer N305 e N306

Selecione a Opção Desejada

Save

(PDF - 0.31 Mb)

Related Products

Compartilhar:

NOVUS Global Privacy Notice

NOVUS is committed to protect the privacy and security of your personal information. The data that you share with NOVUS allows us to provide a better experience when you use our products and services. We guarantee total privacy to your data, used exclusively for communications between NOVUS and you.

In this statement we affirm:

  1. NOVUS does not sell or negotiate customer information;
  2. Your data are stored in secure and controlled environment;
  3. We use your data only for communications of your interest;
  4. At any time you may opt out of the list;

Please see our complete Privacy Policy

After read our Privacy Policy, chose the option bellow: